Contact us
CIBA PCMO 40/50 (API CD/SF) is high quality diesel and gasoline turbo-changer, high performance engine oil, designed for the engine operates at heavy load, high temperature in long-term condition.
Characteristic:
- Excellent lubricant and high loading, due to the oil film to ensure the surface metal protection, reduce friction, anti-wear absolutely.
- Prevent the formation of scale, cleans and disperses all carbon deposits that form during combustion on the parts that keep the engine clean.
- Excellent thermal stability, good oxidation stability and high viscosity stability, which helps to maintain performance, including long-term and continuous engines.
Application:
- For diesel and gasoline engines that require API CF quality.
- Used for heavy transport on road: trucks, passenger’s cars, car of all kinds, or the river: tug boat, barges of all kinds.
- Use for boats, fishing vessels, fishing vessels in the sea for short or long days.
- Used for diesel and gasoline engine in industrial, generator, agriculture, construction.
Ingredient:
Refined mineral oils and the most advanced additives.
Specifications and Approvals:
SAE 15W/40, 20W/50; API CF/SF;
MIL – L – 46152E, MIL – L – 2140F; MB 227.1; VW 505.00; MAN 271; CCMC D2/G2.
Technical Data
Technical specifications | Test method | 15W/40 | 20W/50 |
---|---|---|---|
Density at 15oC (Kg/l) | ASTM D 4052 | 0.86–0.89 | 0.86–0.89 |
Kinematic viscosity at 100oC (mm2/s) | ASTM D 445 | 14-16 | 19–21 |
Viscosity Index (VI) | ASTM D 2270 | Min 110 | Min 110 |
Pour point (oC) | ASTM D 97 | Max -18 | Max -18 |
Flash Point COC (oC) | ASTM D 92 | Min 230 | Min 230 |
Total base number (mgKOH/g) | ASTM D 2896 | Min 9.0 | Min 9.0 |
Water content by vol/mass (%V) | ASTM D 95 | Max 0.05 | Max 0.05 |
Foaming characteristic at 93,5oC (ml/ml) | ASTM D 892 | Max 10/0 | Max 10/0 |
(These characteristics are typical of current production, not constitute specifications).
Preservation and Safety
- Storage in a covered warehouse.
- Store temperature should not exceed 60oC.
- Keep off sparks and flammable materials. Storage must be covered carefully and away from the risk of contamination.
- Used oil must be treated properly, don’t pour directly into ditches , water sources.